AS590 motor soft starter control board

AS590 motor soft starter control boardThe AS590 motor soft start trigger board is a simplified version of the 580 series. It adopts a 32-bit high-performance microprocessor and a highly digital milita

AS590 motor soft starter control board

AS590 motor soft starter control board

The AS590 motor soft start trigger board is a simplified version of the 580 series. It adopts a 32-bit high-performance microprocessor and a highly digital military quality design. It is specially designed for three-phase AC motor soft start occasions with bypass output control. Function parameter setting adopts key operation, fault alarm, interface parameter adopts LCD liquid crystal screen Chinese display, setting parameter is automatically stored. The soft start mode is voltage ramp, voltage sudden jump and current limit soft start, so that the motor can achieve a smooth start under any working conditions, protect the drag system, reduce the impact of the starting current on the power grid, and ensure the smooth deceleration and soft stop of the motor , It effectively solves the parking surge problem of the inertial system, eliminates the feedback impact of the drag system, and can adjust various parameters in the starting process according to the characteristics of the motor load, such as overcurrent value, starting time, control panel belt Power-on soft start, soft stop, over-current protection, working status indication. With thyristor anti-parallel AC trigger mode, it can trigger SCR below 1000A, and it is suitable for various load types such as three-phase AC motor soft start in various fields of industry.

By controlling the starting voltage of the motor, excessive peak values of starting torque and starting current are avoided. On the one hand, the working machine can be protected from excessive acceleration torque stress during the start of the AC motor, and on the other hand, the power supply system can be prevented from being impacted by excessive starting current, which greatly reduces the mechanical stress on the conveyed object. , Reduce the wear of working machinery and transmission parts, so as to reduce maintenance, ensure work safety and extend the service life of equipment.

The soft-start thyristor trigger board has good reliability and stability, strong anti-interference ability, unique anti-interference measures, normal operation in harsh interference environments, complete self-diagnosis and motor operation protection functions of the soft-start board, power failure protection, silicon wear Protection, overload protection, phase sequence protection, phase failure protection, etc. Therefore, all kinds of interference and fault signals from external or internal production will make the performance of the soft start board safer and more reliable because of the above protection functions. All outputs adopt isolation technology, which has a wide range of applications and has complete fault and alarm detection and Protection function, all parameters are digital, no temperature drift changes, improve the regulation accuracy and power utilization efficiency.

Main application of soft start trigger board:

a. In the field of fan use: it can realize the smooth start of the motor, reduce the mechanical impact and belt wear caused by other starting methods, thereby extending the service life of the equipment and ensuring the safe operation of the equipment.

b. In the field of water pump use: the soft stop function can eliminate the water hammer effect caused by high water pressure when the pump is stopped.

c. In the application field of conveying machinery: smooth start of the motor can be realized, so that product shifting or material shaking off due to jitter can be avoided during the conveying.

1. Performance characteristics:

1.1. Powerful human-computer interaction interface, LCD display Chinese menu operation, more intuitive display and more convenient operation;

1.2. Industrial 32-bit microprocessor, SMD chip technology, multiple anti-interference design to ensure the stability and reliability of the industrial environment;

1.3. Abundant starting modes, with voltage ramp, sudden jump and current limiting modes to choose from, and the initial starting voltage and current values of the motor are digitally adjustable;

1.4. Perfect fault detection and alarm function, real-time detection of load status, load current, control signal, feedback signal loss and other parameters;

1.5. Phase loss protection: monitor and detect the three-phase phase loss of the incoming and outgoing terminals, and control the load to stop output in real time;

1.6. Silicon penetration protection: In the non-starting or stopping state, if there is a thyristor breakdown, it will refuse to start and display the fault type parameters, and the alarm relay will output at the same time;

1.7. Overload protection: multiple starting overload protection levels and running overload protection levels, with six different inverse time protection curves set inside;

1.8. Motor soft start: When starting, use different soft start methods to eliminate the impact of the motor on the grid and itself during the initial operation of the motor. The soft start time parameter can be set;

1.9. Motor soft stop: When stopping, in order to eliminate the impact on the power grid and itself when the motor stops, the soft stop time parameter can be set, or it can be set as free stop;

1.10. With the function of automatically identifying the phase sequence, the main circuit power supply can be selected without phase sequence or with phase sequence, which is convenient for debugging and wiring;

1.11. Bypass selection: The bypass output can be closed or opened by setting the bypass selection parameters. When the bypass is opened, it has the bypass contactor closure detection function;

1.12, with running time query function, record the current running time and accumulated running time;

1.13. Dynamic fault record query function, which can continuously record the latest eight historical fault information, so as to find the cause of the fault;

1.14. Complete peripheral interfaces: one 4-20mA analog signal output interface, three relay output interfaces, with flexible operability;

1.15. The control board has the function of detecting the unbalance of the three-phase current of the motor, and the motor will automatically stop when the windings are open phase or leakage, or open circuit between turns.

2. Technical specifications:

2.1. Power supply: 380Vac ±15% 50HZ

2.2. Rated working voltage Ue: AC380V +/-15% 50HZ

2.3. Rated working current Ie: 10~250A

2.4. Initial starting voltage: 25~90%

2.5. Soft start mode: voltage ramp and limited current start, voltage sudden jump start, constant current start

2.6. Parking method: soft parking, free parking

2.7. Soft start time: 1~200 seconds

2.8. Soft parking time: 0~200 seconds

2.9. Alarm relay contact capacity: 250Vac/10A

2.10. Current transformer: 1A standard transformer signal

2.11 Overcurrent characteristics: 6Ie/8S

2.12, Dielectric Strength: 3500 VRMS

2.13. Starting frequency: the time interval between each starting shall not be less than 5 minutes

2.14. Working environment conditions:

Environment temperature: -20℃~ 60℃

Relative humidity: ≤ 90%RH (no frost)

Indoor installation: no flammable, explosive, corrosive gas, no conductive dust, vibration less than 0.5G

The altitude is lower than 3000 meters, and the capacity level should be lowered appropriately if it exceeds 3000 meters.

2.15. Dimensions: 200X140X40mm Opening size: 185X125mm