Delay switch 1 relay module, 5v12v trigger delay disconnection and power failure Automatic timing cycle
0.1 second (minimum) ~ 999 minutes (maximum) continuously adjustable
This product is easy to use and powerful, but buyers please read the operation instructions of this product in detail. It is a very practical product.
This kind of module is a kind of electronic components, please purchase without relevant professional knowledge in order to avoid unnecessary trouble, please buy it carefully, or buy it after you understand it.
Operating mode:
P1: After the signal is triggered, the relay is turned on for OP time, and then turned off; during OP time, the following operations
P1.1: The signal is invalid when triggered again
P1.2: The signal triggers again to re-timing
P1.3: The signal triggers the reset again, the relay is disconnected, and the timing stops;
P-2: Give the trigger signal, after the relay is turned off for CL time, the relay is turned on for OP time, after the timing is completed, the relay is turned off;
P3.1: Give the trigger signal, after the relay is turned on for the OP time, the relay will disconnect CL time, and then cycle the above actions, give the signal again in the cycle, the relay will disconnect, and stop timing; the number of cycles (LOP) can be set;
P3.2: There is no need to trigger signal after power-on, the OP time of relay conduction, CL time of relay disconnection, cycle the above actions; the number of cycles (LOP) can be set;
P-4: Signal hold function. If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing the OP; during the timing, there is another signal, and the timer is cleared;
Timing range
0.1 second (minimum) ~ 999 minutes (maximum) continuously adjustable
How to choose the timing range:
After setting the parameter value in the mode selection interface, short press the STOP button to select the timing range;
XXX. The decimal point is in the ones place, timing range: 1 second to 999 seconds
XX.X The decimal point is in ten's place, timing range: 0.1 second to 99.9 seconds
X.X.X. All decimal points are lit, timing range: 1 minute to 999 minutes
For example, if you want to set the OP to 3.2 seconds, then move the decimal point to the tens place, and the digital tube will display 03.2
Parameter description: OP on time, CL off time, LOP cycle times (1—999 times, "---" represents infinite cycles)
These parameters are independent of each other, but all modes share these parameters. For example, when the on-time OP is set to 5 seconds in P1.1, and the user wants to switch to P1.2 mode, then enter P1.2 to set the corresponding parameters, OP It will also be 5 seconds;
In the main interface (display 000), short press the SET button, OP (CL, LOP) and the corresponding time XXX will be displayed;
If there is only OP (such as mode P1.1, P1.2, P1.3) time in the mode, then short press the SET key will only display OP and the corresponding time;
If there are OP, CL, LOP in the mode (for example, mode P3.1, P3.2), short pressing the SET key will display OP and corresponding time, CL and corresponding time, LOP and corresponding times;
After setting the mode, you can easily view the parameters set in the current mode by short pressing the SET button on the main interface, which is very convenient!
How to set parameters
1. First determine the working mode of the relay;
2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), and then enter the main interface,) "Long press the SET button for 2 seconds and then release "Enter the mode selection interface, select the mode to be set by short pressing the UP and DOWN buttons (P1.1~P-4);
3. After selecting the mode to be set (for example, P3.2), short press the SET button to set the corresponding parameters, then the parameters to be set will flash (OP on time, CL off time, LOP cycle times ("-- -" represents infinite cycles)), adjust the parameter value through UP and DOWN, support long press (rapid increase or decrease) and short press (increase or decrease by 1 unit); after setting the parameter value, short press the STOP button To select the position of the decimal point, select the timing range (corresponding time 0.1 seconds to 999 minutes); short press the SET key to set the next parameter of the current mode, the process is the same as above;
4. After setting the parameters of the selected mode, press and hold the SET button for 2 seconds and then release it. The currently set mode will flash, and then return to the main interface. The parameter setting is successful, very simple!
Main interface: "000" (no decimal point) is displayed when the relay is not working, and there is a decimal point when the relay is working, which is very clear!
Mode selection interface: Long press the SET button to enter, after the setting is completed, long press the SET button to exit and return to the main interface, very simple!
STOP button function expansion:
Relay enable mode:
1. ON: the relay is allowed to conduct during OP conduction;
2. OFF: The relay is forbidden to conduct and is always off;
Short press the STOP button on the main interface to switch between ON and OFF, the current state will flash, and then return to the main interface. (This function is an emergency stop function, one key to open the closed relay)
Sleep mode:
1. C-L sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, and the program runs normally;
2. O-d normal mode: the digital tube is always on for display;
Long press the STOP button for 2 seconds and then release it to switch between C-L and O-d states. The current state will flash, and then return to the main interface.